A Smart Lamb-Wave Sensor System for the Determination of Fluid Properties by Michael Johannes Vellekoop

Cover of: A Smart Lamb-Wave Sensor System for the Determination of Fluid Properties | Michael Johannes Vellekoop

Published by Delft Univ Pr .

Written in English

Read online

Subjects:

  • Electromagnetic Waves Propagation,
  • Electronic Apparatus And Devices,
  • Science/Mathematics

Book details

The Physical Object
FormatPaperback
Number of Pages137
ID Numbers
Open LibraryOL12803393M
ISBN 109040710368
ISBN 109789040710360

Download A Smart Lamb-Wave Sensor System for the Determination of Fluid Properties

A Smart Lamb-Wave Sensor System for the Determination of Fluid Properties [Michael Johannes Vellekoop] on *FREE* shipping on qualifying offers. A smart lamb-wave sensor system for the determination of fluid properties ().Cited by: 7. A smart lamb-wave sensor system for the determination of fluid properties.

By M.J. (author) Vellekoop. Abstract. Electrical Engineering, Mathematics and Computer SciencAuthor: M.J. (author) Vellekoop. is a platform for academics to share research papers. For our application, this sensor is used in reflectometry. Then, the reflected A 1 Lamb mode can only be received.

Lamb Wave Propagation in the Plate for Free Boundary To characterize a fluid in contact at the end of the plate, the understanding of the unloaded sensor behavior is required. InCited by: We describe the fluid loading of Lamb waves propagating in a 3 mm×9 mm composite membrane consisting of low‐stress silicon nitride deposited by low‐pressure chemical vapor deposition ( μm thick) supporting an aluminum ground plane ( μm), a piezoelectric zinc oxide layer ( μm), and a pair of ‐μm‐period interdigital Al transducers ( μm).

A more expansive view of a Smart Sensor System, which is used in this article, is illustrated in Fig. a complete self-contained sensor system that. In practice, the plate serving as a waveguide is often A Smart Lamb-Wave Sensor System for the Determination of Fluid Properties book contact with a fluid, either on one or both sides.

The mutual interaction between the guided wave in the plate and the pressure wave in the fluid will, henceforth, be referred to as fluid loading of the plate.

While the energy of waves propagating in a free plate is strictly confined within the structure, fluid loading will usually lead.

About this book With contributions from an internationally-renowned group of experts, this book uses a multidisciplinary approach to review recent developments in the field of smart sensor systems, providing complete coverage of all important system and design aspects, their building blocks and methods of signal processing.

The smart sensors have main advantages of fast signal conditioning, higher signal-to-noise ratio, self testing, auto calibration, small physical size, high reliability, failure prevention and.

Pressure is force per area. If a fluid is at rest, one refers to static pressure. If a fluid is in motion, one refers to dynamic pressure, which is a function of the motion of the fluid. The relationship between gauge pressure is the difference between absolute pressure and atmospheric pressure.

For example, a flat tire on an automobile is said. Badcock, R.A., Birt, E.A.: The use of piezocomposite embedded Lamb wave sensors for detection of damage in advanced fibre composites. Smart Materials and Structures 9. Sensors •1) Active sensors: Require an external source of power (excitation voltage) that provides the majority of the output power of the signal •2) Passive sensors: The output power is almost entirely provided by the measured signal without an excitation voltage.

The SMART FLUID TECH Company based in Dhaka & Chattagram in Bangladesh and for a long time has been developing product lines and systems for metering liquids and solutions for Chemical Dosing Pump, Centrifugal pump, Online Measuring Controlling system for PH, ORP, Chlorine, Conductivity & DO, Multistage Pump, Drinking Water Treatment, Waste Water Treatment, STP, Swimming Pool.

Other physical properties as for example X- β- or Γ- radiation may form the basis for a chemical sensor in case they are used for determination of chemical composition. The main transduction elements in food analysis sensors are electrochemical devices, such as ion-selective electrodes (ISE), ion-selective field effect transistors (FET.

With an integrated active piezoelectric sensor network, a Lamb wave-based crack identification technique for aluminium plates was developed.

Experimental results showed that the propagation of Lamb waves in aluminium plate-like structures is considerably complicated due to wave dispersion, material attenuation, boundary reflection, etc.

This book is a general introduction to intelligent or smart materials, systems and machines. Presented in understandable and non-mathematical terms, it is for anyone who is interested in future developments in these fields or who needs to be briefed on the current status of these interdisciplinary technologies.

In this paper, a novel AlN based acoustic wave sensor is developed for decoupling viscosity and density. Multiple higher order modes of Lamb waves are generated in this sensor and employed to interact with the adjacent liquid under test.

TUTORIAL 2 – SENSORS AND PRIMARY TRANSDUCERS This tutorialprovides an overview of instrument sensors used in process and automatic control. It is useful to anyone studying measurement systems and instrumentation but it is provided mainly in support of the EC module D – Control System Engineering.

This tutorial is mainly descriptive. About this book With contributions from an internationally-renowned group of experts, this book uses a multidisciplinary approach to review recent developments in the field of smart sensor systems, covering important system and design aspects.

The basic tenet of smart sensors is that the sensor complexities must be concealed internally and must be transparent to the host system.

Smart sensors are designed to present a simple face to the host structure via a digital interface, such that the complexity is borne by the sensor and not by the central signal processing system. Smart Sensor System SE NS OR S User Commands for Sensor Operation Fig.

A smart sensor system as presented herein. The core of a stand-alone smart sensor system includes sensors, power, communication, and signal processing.

RESISTANCE TEMPERATURE DEVICE (RTD) Very Accurate and stable Reasonably wide temperature range More expensive (platinum) Positive Temperature Constant, and rather constant Requires current excitation Smaller Resistance range Self-heating is a concern Lead resistance is a concern Read AN for more details (e.g.

current excitation circuit). Written by experts in their area of research, this book has outlined the current status of the fundamentals and analytical concepts, modelling and design issues, technical details and practical applications of different types of sensors and discussed about the trends of next generation of sensors and systems happening in the area of Sensing technology.

the integration of a total physical and chemical analysis system in the one IC package, leading to the evolution of smart sensors. Introduction Acoustic wave (AW) devices have received increasing interest in recent years in a wide range of applications where they are currently used as resonators, filters, sensors and actuators.

In this paper, a liquid multi-parameter decoupling method with only one Lamb wave sensor is presented. In a Lamb wave sensor, antisymmetric modes (A01 mode for low frequency, A03 mode for high frequency) and symmetric modes (S0 mode) are used to detect multiple parameters of a liquid, such as its density, sound velocity, and viscosity.

We found they can play very different roles in the detections. Whether for continuous level measurement, point level measurement or both – SICK offers a wide range of solutions for process engineering, storage, and protection.

Based on the installation situation, medium properties, and ambient conditions, SICK provides sensors that ensure efficient processes. As the provider of one of the broadest technology portfolios, SICK brings its knowledge to the. The reed switch activated level sensor is the ideal technology for monitoring automotive fluid levels where the sensor has to \൷ork over a wide temperature range and in very dirty environments.

That is why they are selected for monitoring fuel levels, en對gine oil, ABS \⠀愀甀琀漀洀愀琀椀挀 戀爀愀欀椀渀最. A pulse laser combined LWT technique with a two-stage reconstruction algorithm was proposed to realize rapid damage location, or even the evaluation of damage size for plate-like structures.

Since the amplitude of Lamb waves in propagation is highly sensitive to damage, including inside damage, the change of the attenuation coefficient of Lamb waves in the inspection region was used as a. When integrating smart sensors or other electronics into a fluid power system—or any system for that matter—packaging is critical.

These components typically have very sensitive parts which must be protected, especially in fluid power applications where there are high pressures and temperatures that could negatively impact the results of.

The Smart Sensors, Measurement and Instrumentation series (SSMI) publishes new developments and advancements in the fields of Sensors, Instrumentation and Measurement technologies. The series focuses on all aspects of design, development, implementation, operation and applications of intelligent and smart sensors, sensor network.

SICK sensors detect the position of all kinds of object. Location, format, navigation – all are identified and sent to the relevant control Position determination; Position determination. Show all Hide all. Fluid sensors.

Fork sensors. Gas Analyzers. Glare sensors. Identification solutions. Inductive proximity sensors. Inertial sensors. Hall Effect 60 Chemical Sensors 60 Improving Sensor Characteristics 61 Digital Output Sensors 62 Incremental Optical Encoders 63 Digital Techniques 64 Noise/Interference Aspects 65 Low-Power, Low-Voltage Sensors 66 Impedance 67 Analysis of Sensitivity Improvement 67 Thin Diaphragm 67 Increased Diaphragm Area Vellekoop M J, Lubking G W, Sarro P M, et al.

Evaluation of liquid properties using a silicon lamb wave sensor. Sens Actuator A-Phys,43(2): – CrossRef Google Scholar Provides unique coverage of wireless sensor system applications in space, underwater, underground, and extreme industrial environments in one volume This book covers the challenging aspects of wireless sensor systems and the problems and conditions encountered when applying them in outer space, under the water, below the ground, and in extreme industrial environments.

PIR-sensor-based-automatic-door- opening system circuit mainly consists of a PIR sensor, an micrcontroller, a driver IC, a door motor. PIR Sensor Application If a body movement is present near the door, then infrared radiation emitted from the body will cause the sensor to produce sensing signal which is fed to microcontroller.

Determination of Mechanical Properties of FRP Materials Using the DIC Method Cellulose-Based Hydrogels as Smart, Green and Controllable Nitrogenous Fertilizers Releasing Agents Design and Manufacture of a Magnetorheological Brake System Applicable for Wheelchair Manipulations.

This chapter offers a detailed insight into a dielectric characterization of the materials based on the phase-shift measurements of the transmission signal.

The chapter will provide in-depth theoretical background of the phase-shift transmission line measurement in the microstrip architecture and determination of dielectric permittivity of design under test for several measurement configurations.

Strain Gage: Materials material gage factor, G TCR () Ni80 Cr20 - 10 Pt92 W8 – 24 Silicon (n type) to 70 to Germanium (p type) TCR = temperature coefficient of resistivity (ºC-1) • Note: • G for semiconductor materials ~ x that of metals.

The fluid flow that passes through a metering system having as primary element the diaphragm or the spout cannot be determined directly by evaluating the relation (10) due to the dependency of the discharge coefficient in ratio with the fluid rate, C = f (v).Based on the relations presented in the previously mentioned standard, there has been.

TE's fluid property sensors include DEF sensors and SCR sensors with tuning fork technology and efficient algorithm to provide accurate measurement of viscosity, density and dielectric constant. Our portfolio of fluid property sensors is specifically designed to provide fluid quality and condition monitoring capabilities.This wiring comes at a high installation cost that exceeds the cost of the sensor itself in most cases.

This situation is not improved with a traditional wireless sensor where battery change costs over the life of the sensor are equally painful. Smart Passive Sensing devices are wireless battery-free sensors that eliminate maintenance costs.ASTM standard test methods, and specifications relating to plastics, their raw materials, components, and compounding ingredients, finished products made from plastics such as sheets, rods, tubes, pipes, cellular materials, and molded or fabricated articles.